XY-WJ01 Delay Relay Module Digital LED Dual Display Cycle Timing Circuit

$32.50 Inc. GST

Availability: 46 in stock SKU: 8-3-2-1 Category:
Quantity Discount (%) Price
1 $32.50
2 - 4 5 % $30.88
5 - 9 7.5 % $30.06
10 - 19 10 % $29.25
20 - 49 12.5 % $28.44
50 - 99 15 % $27.63
100+ 17.5 % $26.81
Compare Compare

Description

Introducing the XY-WJ01 Digital LED Dual Display Delay Relay Module – Efficient Cycle Timing Solution

Unlock precise control with the XY-WJ01 Delay Relay Module. Our product boasts a crystal-clear LCD display that offers unmatched simplicity and functionality. Please take a moment to read the user instructions thoroughly for optimal utilization.

Key Features:

  1. Dual-Column LCD Display: Clearly view parameters in real-time.
  2. Versatile Trigger Modes: Choose from high/low levels or switch quantity to match diverse needs.
  3. Wide Power Supply Range: Operates efficiently within 6V to 30V.
  4. UART Parameter Adjustment: Modify parameters effortlessly through UART communication.
  5. Emergency Stop Functionality: A dedicated stop button provides immediate halt control.
  6. Power-Efficient Design: After 5 minutes of inactivity, the module enters low-power mode, reactivated by any action.
  7. Individual Parameter Customization: Tailor OP/CL/LOP parameters to your specific requirements.
  8. Automatic Parameter Saving: All settings are automatically preserved even during power-offs.

Operating Modes (P1~P7):

  • P0: Relay conducts during OP time upon signal trigger, then disconnects; signal is invalid during OP time.
  • P1: Relay conducts during OP time upon signal trigger, then disconnects; new timer triggered during OP time.
  • P2: Relay conducts during OP time upon signal trigger, then disconnects; reset timer with signal during OP time, relay disconnects, and timing stops.
  • P3: Relay disconnects for CL time upon signal trigger, then conducts.
  • P4: Relay conducts during OP time upon signal trigger, then disconnects for CL time; loops with configurable cycles (LOP), maintaining relay disconnected at cycle end.
  • P5: Relay disconnects for CL time upon signal trigger, then conducts during OP time; loops with configurable cycles (LOP), maintaining relay conducting at cycle end.
  • P6: No trigger signal after power-on, relay conducts during OP time, then disconnects for CL time; loops with configurable cycles (LOP), signal invalid in loop.
  • P7: No trigger signal after power-on, relay disconnects for CL time, then conducts during OP time; loops with configurable cycles (LOP), signal invalid in loop.
  • P8: Signal hold function: Signal maintained, timer reset, relay conducts; signal disappearance leads to relay disconnect after OP time; additional signal during timing clears timing.
  • P9: Signal hold function: Signal maintained, timer reset, relay disconnects; signal disappearance leads to relay conducts after CL time; additional signal during timing clears timing.
  • Modes (P0~P7): Short pressing pause button initiates timing if system is not timed; ongoing timing pauses, relay disconnects, “out” flashes for reminders.

Specifications:

  • Timing Range: 0.01 sec to 9999 min
  • Power Supply: 6V to 30V
  • Trigger Signal Source: High level (3.0V~24.0V), Low level (0.0V ~ 0.2V), Switch signal
  • Max Output Load: DC 30V 5A, AC 220V 5A
  • Static Current: 15mA; Operating Current: 50mA
  • Service Life: 100,000+ cycles; Operating Temperature: -40°C to 85°C
  • Robust Design: Optocoupler isolation, industrial-grade circuit board, enduring memory after power-offs
  • Compact Dimensions: 8×3.8×1.9cm (3.15×1.5×0.75inch)
  • Color: Gray & Black
  • Quantity: 1 Module

Experience ultimate timing precision with the XY-WJ01 Delay Relay Module. Upgrade your control capabilities today!

Additional information

Weight 50 g
Dimensions 80 × 45 × 25 mm

Reviews

There are no reviews yet.


Only logged in customers who have purchased this product may leave a review.